sampling system

Automatic crude oil sampler

HCYZ series crude oil automatic sampler for crude oil (pipeline transportation, shipping, truck handling) sampling field actual situation, in accordance with ISO3171, SY/T5317-2006 two standards desig

HCYZ series crude oil automatic sampler for crude oil (pipeline transportation, shipping, truck handling) sampling field actual situation, in accordance with ISO3171, SY/T5317-2006 two standards designed and manufactured. It is widely used for sample collection of crude oil pipeline transportation, shipping, truck loading and unloading, especially in line with the requirements of accurate measurement at the trade interface;

At present, the crude oil automatic sampler designed and produced by our company takes time and flow ratio samples; And can implement communication remote transmission control. Multiple crude oil pipelines can also be automatically sampled.


The design of the sampler conforms to the standard Q/320323TEB01-2010, SY5317-2006 "Crude Oil Pipeline Automatic Sampling Method" and the international standard ISO3171.


Crude oil sampler product structure diagram:

Flame Arrestor

Technical parameters of crude oil sampler:


通用场景

术语库

1, appearance size: about 660X 660X 1200 (mm), stainless steel shell, and according to user requirements design;


2, power input: a. Voltage: 380V±10%; b. Power: 4.0kW (4*1.5 flame retardant cable can be used)


3, motor power: 0.75kW, 0.37kW;


4, working medium: temperature: 80℃ below; Viscosity: fluidity;


5, pressure: below 4.0Mpa (higher than 4.0Mpa separately designed);


6, the working environment: depending on the freezing point of the medium, below the freezing point should be insulated or electric heat tracing;


7, performance coefficient: 0.95-- 1.05 (better than the international standard of 0.90 -- 1.10);


8, sampling interval time/flow (cycle) : interval time 10-- 999 (s) adjustable, interval flow is adjustable;


9, single sampling amount: 1.5-10 (ml) (adjustable), and can be designed according to user needs;


10. Local control, display, adjustment and communication of relevant parameters are transmitted to the duty room for control, display and adjustment;


11, sampling quantity weighing real-time display, overweight and underweight alarm, power failure, shutdown alarm;


12, the oil pipeline can not reach the turbulent flow, can be taken: 1- local reduction or 2- installation of self-operated rectifier in the pipeline or installation of external circulation pump and jet; Our company recommends local reducing, the effect is outstanding;


13, the sampler does not exist dead oil section, there is no hysteresis;


14, explosion-proof grade: dⅡBT4